    Two decades of condition monitoring methods for power devices

    Get PDF
    Condition monitoring (CM) of power semiconductor devices enhances converter reliability and customer service. Many studies have investigated the semiconductor devices failure modes, the sensor technologies, and the signal processing techniques to optimize the CM. Furthermore, the improvement of power devices’ CM thanks to the use of the Internet of Things and artificial intelligence technologies is rising in smart grids, transportation electrification, and so on. These technologies will be widespread in the future, where more and more smart techniques and smart sensors will enable a better estimation of the state of the health (SOH) of the devices. Considering the increasing use of power converters, CM is essential as the analysis of the data obtained from multiple sensors enables the prediction of the SOH, which, in turn, enables to properly schedule the maintenance, i.e., accounting for the trade-off between the maintenance cost and the cost and issues due to the device failure. From this perspective, this review paper summarizes past developments and recent advances of the various methods with the aim of describing the current state-of-the-art in CM research

    Distortion Due to the Zero Current Detection Circuit in High Power Factor Quasi-Resonant Flybacks

    No full text
    In a high-power factor quasi-resonant Flyback, an ideal zero current detection (ZCD) circuit and control circuitry enable the power switch turn-on in the exact instant a zero ringing current is reached after demagnetization. A nonzero current at the turn-on instant affects the input current shape and; consequently, affects its Total Harmonic Distortion (THD). This paper firstly deeply analyzes the effect on the distortion due to a nonideal ZCD circuit. After, some typical implementations of the ZCD circuit and their effect on the THD are analyzed, identifying their pros and cons. Finally, some experimental results are obtained to validate the analytical investigation

    Distortion Due to the Zero Current Detection Circuit in High Power Factor Quasi-Resonant Flybacks

    No full text
    In a high-power factor quasi-resonant Flyback, an ideal zero current detection (ZCD) circuit and control circuitry enable the power switch turn-on in the exact instant a zero ringing current is reached after demagnetization. A nonzero current at the turn-on instant affects the input current shape and; consequently, affects its Total Harmonic Distortion (THD). This paper firstly deeply analyzes the effect on the distortion due to a nonideal ZCD circuit. After, some typical implementations of the ZCD circuit and their effect on the THD are analyzed, identifying their pros and cons. Finally, some experimental results are obtained to validate the analytical investigation

    Intrusiveness of Power Device Condition Monitoring Methods:Introducing Figures of Merit for Condition Monitoring